I’m syncoiding from my normal RAIDz2 to a backup mirror made of 2 disks. I looked at zpool iostat and I noticed that one of the disks consistently shows less than half the write IOPS of the other:

                                        capacity     operations     bandwidth 
pool                                  alloc   free   read  write   read  write
------------------------------------  -----  -----  -----  -----  -----  -----
storage-volume-backup                 5.03T  11.3T      0    867      0   330M
  mirror-0                            5.03T  11.3T      0    867      0   330M
    wwn-0x5000c500e8736faf                -      -      0    212      0   164M
    wwn-0x5000c500e8737337                -      -      0    654      0   165M

This is also evident in iostat:

     f/s f_await  aqu-sz  %util Device
    0.00    0.00    3.48  46.2% sda
    0.00    0.00    8.10  99.7% sdb

The difference is also evident in the temperatures of the disks. The busier disk is 4 degrees warmer than the other. The disks are identical on paper and bought at the same time.

Is this behaviour expected?

  • themoonisacheese@sh.itjust.works
    link
    fedilink
    English
    arrow-up
    2
    ·
    2 months ago

    It’s a gigabyte ab350m gaming-3 rev 1.0. it boots grub fine but then crashes right after displaying “loading Linux 6.x”, CPU led flashes then dram led stays on, I have to turn it off with the PSU switch.

    Either it’s a rev 1.0 bug which is a thing on those motherboards, or the CPU (or igpu) is defective.

    https://superuser.com/questions/1854228/proxmox-doesnt-boot-after-cpu-change

    I’m currently waiting on support from both the seller and gigabyte but I don’t expect anything out of it, though I’m still yet to test it in a different motherboard.